MONSEL3=0, MONSEL1=0, PGAMON=Others, MONSEL0=0, MONSEL2=0
Programable Gain Amp Monitor Output Control Register
PGAMON | PGA Monitor Signal Selection 0 (0x0): Not select monitor signal (Hi-Z) 0 (Others): Setting prohibited 1 (0x1): PGA output |
MONSEL0 | PGA Unit 0 Monitor Output Enable 0 (0): Disable monitor output 1 (1): Enable monitor output |
MONSEL1 | PGA Unit 1 Monitor Output Enable 0 (0): Disable monitor output 1 (1): Enable monitor output |
MONSEL2 | PGA Unit 2 Monitor Output Enable 0 (0): Disable monitor output 1 (1): Enable monitor output |
MONSEL3 | PGA Unit 3 Monitor Output Enable 0 (0): Disable monitor output 1 (1): Enable monitor output |